Skip to main content
toiletnearest.com Search Open the map

What makes a toilet wheelchair accessible?

A wheelchair accessible toilet gives enough clear floor beside the toilet to transfer from a wheelchair, room to turn, a seat at about chair height, and grab rails at set heights. The exact sizes are national: England, the US, Australia and Germany each set their own, so a toilet that meets one country's rules can feel different in another.

Find a wheelchair accessible toilet near you

Last updated

The short answer

  • Space to transfer. The toilet sits near one wall with a clear space on the other side, so a wheelchair can pull up alongside. That side is called the transfer side.
  • Room to turn. England asks for a 1500 by 1500 mm turning space in the room; the US asks for a 60 inch (1525 mm) circle or a T-shaped space.
  • A seat at about chair height. 480 mm in England, 17 to 19 inches (430 to 485 mm) in the US, 460 to 480 mm in Australia.
  • Rails you can trust. A rail on the wall beside the toilet and one on the open side or behind, at a set height and strong enough to take a person's weight.
  • A door and route you can use. Wide enough, step-free and close to where people are.

To find one, use our wheelchair accessible toilet finder. If you are travelling, our guide to accessible toilets abroad covers keys and layouts country by country.

The figures side by side

These are the minimums or ranges each country's rules set for a toilet used by wheelchair users. Each country measures some things differently, so read the notes under each section before comparing two numbers.

Key figures for a wheelchair accessible toilet. England: Approved Document M Volume 2. US: 2010 ADA Standards. Australia: AS 1428.1-2021 as summarised by the Western Australian and Tasmanian governments. Germany: DIN 18040-1 as summarised by HEWI.
FigureEnglandUnited StatesAustraliaGermany
Seat height480 mm17–19 in (430–485 mm)460–480 mmNot given in our source
Toilet centre line from side wall500 mm16–18 in (405–455 mm)450–460 mmRails on both sides instead
Front of pan from back wall750 mmNot set800 mm ± 10 mmBack support 55 cm behind the front edge
Horizontal rail height680 mm33–36 in (840–915 mm) to the topSet in AS 1428.1Top 28 cm above the seat
Room or clear space2200 x 1500 mm room60 x 56 in (1525 x 1420 mm) at the toilet1900 x 2300 mmNot given in our source
Seat and grab rail heights at the same scale: 480 mm and 680 mm in England (Approved Document M), and 17 to 19 inches and 33 to 36 inches in the US (2010 ADA Standards).

England: Approved Document M

Approved Document M Volume 2 is the official guidance for meeting the access part of the Building Regulations in England, for buildings other than homes. It says a self-contained unisex toilet is always the preferred option for wheelchair users, because a partner or carer of a different sex can go in to help. A unisex accessible toilet should always be provided in addition to any wheelchair-accessible cubicles inside the men's and women's toilets, not replaced by them.

England's corner layout, simplified from Approved Document M Diagram 18, for a right-hand transfer: a room at least 2200 by 1500 mm, the toilet centre 500 mm from the side wall, a drop-down rail on the open side and a 1500 by 1500 mm turning space.

The room

  • At least 2200 mm deep and 1500 mm wide, not counting any radiator that sticks out.
  • If it is the only toilet in the building, 2000 mm wide, with a standing-height washbasin as well as the small basin beside the toilet.
  • A 1500 by 1500 mm wheelchair turning space.
  • The toilet in a corner: its centre line 500 mm from the side wall, the front of the pan 750 mm from the back wall, and at least 1000 mm from the centre line to the opposite wall. The transfer space beside it is kept clear right back to the wall.
  • The door preferably opens outwards and has a horizontal bar on the inside to pull it shut.

Rails, seat and flush

  • A drop-down rail on the open side, 320 mm from the toilet's centre line, at the same height as the other horizontal rails.
  • A grab rail fixed to the side wall. If it sits close to the wall, a second drop-down rail is added on the wall side; if its centre line is 400 mm from the toilet's centre line, no second drop-down rail is needed.
  • Horizontal rails 680 mm above the floor and a seat at 480 mm, allowing for the pan maker's tolerance.
  • The flush handle on the open, transfer side, whichever way round the room is, and a pan that will take a raised seat (the key dimensions of BS EN 997).
  • An emergency alarm pull cord, red, with two bangles: one at 100 mm and one at 800 to 1000 mm above the floor, so someone who has fallen can reach it.

Where and how many

Approved Document M asks for at least one accessible unisex toilet wherever toilets are provided for customers, visitors or staff, with no wheelchair user having to travel more than 40 m on the same floor to reach one. Where there are several, there should be a choice of left- and right-hand layouts, and in buildings of several floors they can alternate floor by floor. It also says these toilets should not be used for baby changing. For more detail on transfer methods and fittings, it points to BS 8300.

Some disabled people need more than this: a hoist, an adult-sized changing bench and more space. That is a Changing Places toilet, and Approved Document M requires one in some large buildings, such as shopping centres of 30,000 m² or more and hospitals. In the UK, many standard accessible toilets are locked with a RADAR key.

United States: the ADA Standards

The 2010 ADA Standards for Accessible Design set the rules for new and altered buildings under the Americans with Disabilities Act. Where toilets are provided, at least one must meet the standard, and where there are toilet compartments, at least one must be wheelchair accessible.

Clearance and grab bars at an accessible toilet under the 2010 ADA Standards: a clear space at least 60 inches from the side wall and 56 inches from the rear wall, the toilet centre 16 to 18 inches from the side wall, and grab bars on the side and rear walls.

The toilet and its clearance

  • A wall or partition behind the toilet and one beside it, with the toilet centre line 16 to 18 inches (405 to 455 mm) from the side wall.
  • Clear floor at least 60 inches (1525 mm) measured from the side wall and 56 inches (1420 mm) from the rear wall. Grab bars and dispensers may overlap it; a washbasin may not, except in homes.
  • A seat 17 to 19 inches (430 to 485 mm) high to the top of the seat, not sprung to flip up.
  • The flush control on the open side, worked by hand or automatic.
  • The toilet paper dispenser 7 to 9 inches (180 to 230 mm) in front of the toilet, its outlet 15 to 48 inches (380 to 1220 mm) above the floor, never behind a grab bar.

Grab bars

  • Side wall: at least 42 inches (1065 mm) long, starting no more than 12 inches (305 mm) from the rear wall and reaching at least 54 inches (1370 mm) from it.
  • Rear wall: at least 36 inches (915 mm) long, running at least 12 inches (305 mm) from the toilet's centre line on one side and 24 inches (610 mm) on the other.
  • Mounted 33 to 36 inches (840 to 915 mm) above the floor, measured to the top of the gripping surface.
  • Round bars 1¼ to 2 inches (32 to 51 mm) across, with exactly 1½ inches (38 mm) between the bar and the wall.
  • The bar, fixings and wall must take a force of 250 pounds (1112 N) at any point, and the bar must not rotate in its fittings.

The room and the compartment

A toilet room needs a turning space: a 60 inch (1525 mm) circle or a T-shape within a 60 inch square. A wheelchair accessible compartment is at least 60 inches (1525 mm) wide and 56 inches (1420 mm) deep with a wall-hung toilet, or 59 inches (1500 mm) with a floor-mounted one. Doors need a clear opening of at least 32 inches (815 mm). The Access Board's guide also gives advisory figures for toilets used mainly by children. Read more in our guide to US restrooms.

Australia: AS 1428.1

Australia's National Construction Code requires the circulation spaces, fixtures and fittings of accessible toilets to comply with the standard AS 1428.1. Where a building has two or more accessible unisex toilets, left- and right-handed mirror-image layouts must be split as evenly as possible, because, as the Code's guidance says, some people transfer from the right and some from the left.

Tasmania's Anti-Discrimination Commissioner sums up what a new accessible unisex toilet must have: a doorway at least 850 mm wide; at least 1900 mm by 2300 mm of space inside to turn and reach the pan and basin; grab rails beside and behind the pan; a backrest; and nothing stored in the room. One side of the pan must be clear of walls so that people can transfer from the front or the side.

The Western Australian government's technical note on AS 1428.1-2021 gives the pan figures: the top of the seat 460 to 480 mm above the floor, the front of the pan 800 mm ± 10 mm from the back wall, and its centre line 450 to 460 mm from the side wall. The backrest is 350 to 400 mm wide and 150 to 200 mm tall, 120 to 150 mm above the seat, and angled at 95 to 100 degrees to it.

An Australian accessible toilet pan in side view, after the Western Australian government's note on AS 1428.1-2021: the seat top 460 to 480 mm high, the front of the pan 800 mm (± 10 mm) from the back wall, and a backrest above the seat.

Many Australian accessible toilets are locked with an MLAK key; see toilets in Australia.

Germany: DIN 18040-1

The most visible difference in Germany is the rails. According to HEWI, a German maker of accessible bathroom fittings, DIN 18040-1 requires a folding support rail on both sides of the toilet in public buildings. The top of each rail is 28 cm above the seat, the rails extend 15 cm beyond the front of the seat, and HEWI recommends 65 to 70 cm clear between them. A back support sits 55 cm behind the front edge of the bowl. If you are used to a fixed wall rail on one side, a German toilet gives you a rail to fold down on either side instead. More in toilets in Germany.

Ambulant cubicles

Not everyone who needs an accessible toilet uses a wheelchair. An ambulant cubicle is an ordinary-sized cubicle with rails on both sides, for people who use crutches or a walking frame, or who need support to sit and stand.

  • England: Approved Document M Diagram 21 shows a cubicle at least 1465 mm deep and 920 mm wide, with a 600 mm horizontal rail at 680 mm and a 600 mm vertical rail starting at 800 mm. Where a block has four or more cubicles, one should be an enlarged cubicle 1200 mm wide.
  • United States: at least 60 inches (1525 mm) deep and 35 to 37 inches (890 to 940 mm) wide, with a side grab bar on both sides. One is required, as well as the wheelchair compartment, where a toilet room has six or more toilets and urinals.
  • Australia: between 900 mm and 920 mm wide, so that a person can reach both rails, with at least 900 mm clear in front of the pan that the door does not swing into.

If you can walk but have urgent needs rather than mobility needs, a Can't Wait card may help more than any key.

At home

These rules are for public buildings. Homes are treated more loosely: in the US, for example, the ADA Standards allow a seat as low as 15 inches (380 mm) in homes, and grab bars can be left off as long as the wall has been reinforced so they can be fitted later. You can still borrow the public figures. They are a sound starting point for a home bathroom, adjusted for the person who will use it:

What our map records

Our maps record whether a toilet is accessible; they cannot say which standard it was built to or which side the rails are on. In the UK, 6,330 of the 15,817 public toilets in our data (40%) have a record marked accessible. Elsewhere we use OpenStreetMap, where mappers tag a toilet wheelchair=yes for full, step-free access. In the cities we hold, 313 of 887 toilets mapped in United States (35%), 607 of 1,325 toilets mapped in Australia (46%) and 637 of 1,225 toilets mapped in Germany (52%) are tagged that way. An untagged toilet is unknown, not inaccessible.

Before you rely on one, check the details that matter to you. See all of them on the wheelchair accessible toilet map.

Common questions

How big is a wheelchair accessible toilet?

In England, Approved Document M shows a unisex wheelchair-accessible toilet at least 2200 mm deep and 1500 mm wide, or 2000 mm wide if it is the only toilet in the building. Tasmania's Anti-Discrimination Commissioner gives at least 1900 mm by 2300 mm for a new accessible unisex toilet in Australia. The US ADA Standards set the clear space at the toilet itself at 60 by 56 inches (1525 by 1420 mm) minimum.

How high should an accessible toilet seat be?

Approved Document M shows 480 mm in England. The ADA Standards set 17 to 19 inches (430 to 485 mm) to the top of the seat. The Western Australian government's note on AS 1428.1-2021 gives a seat top of 460 to 480 mm.

How high should grab rails be beside a toilet?

Approved Document M shows horizontal rails at 680 mm in England. The ADA Standards set 33 to 36 inches (840 to 915 mm) to the top of the gripping surface. In Germany, HEWI's summary of DIN 18040 puts the top of folding rails 28 cm above the seat.

What is an ambulant toilet?

A narrow cubicle with grab rails on both sides, for people who can walk but need support, such as people using crutches. It is not meant for wheelchairs. England, the US and Australia all require one in larger toilet blocks in addition to the wheelchair-accessible toilet.